            Home > Products & Services > Cooling Towers > Series 3000

            Series 3000

            2. Benefits

            Date : 2013-09-20 16:29

            Reduced Energy Consumption

            • - Most efficient cooling tower in the industry
            • - Up to a 16% increase in capacity
            • - Exceeds ASHRAE 90.1-2013 efficiency requirements
            image002

            Energy Cost Savings Based on a 400-Ton System ($0.12 kWH)

            填充圖片

            400-Ton Example

            Series 3000

            Competition

            Competition

            Fan (KW)

            15

            22

            30

            Footprint (mm)

            2588 x 5481 x 3654

            2588 x 5481 x 3654

            2588 x 5481 x 3654

            Capacity (NT)

            400

            386

            423

            填充圖片

            More Selection Flexibility

            • - 31 new models
            • - 3 new box sizes
            • -?69 XE-Series 3000 Cooling Tower?models are available in a full array of box sizes

            填充圖片

            Enhanced Payback Analysis

            • - Provides alternative selections based on energy savings and minimum payback
            • - User-defined life-cycle cost inputs
            • - XE-Series models featured in?selection program
            ?image003
            ?Enhanced Product Selection Software

            填充圖片

            Low Environmental Impact

            • - Energy Efficient
            • ? a. Meets or exceeds ASHRAE Standard 90.1 energy efficiency requirements
            • ? b. Premium efficient/inverter duty fan motors
            • ? c. Gravity distribution system with low pump head requirements
            • - Sound Reduction Options
            • ? a. Standard fan is high efficiency and low sound
            • ? b. ?For further reduced sound levels, Low Sound Fans, Whisper Quiet Fans, and sound attenuation are available options

            填充圖片

            Durable Construction

            • - Meets wind and seismic requirements of the International Building Code (IBC)
            • - Designed to withstand wind loads up to 60 psf, upgraded units designed to withstand 82 psf
            • - Seismically verified through dynamic shake table testing up to a SDSof 3.10g
            image004

            Shake Table Testedbj

            填充圖片

            • - Listed on California’s Office of Statewide Health Planning and Development (OSHPD) pre-approved equipment list
            • - Casing panels constructed of corrosion resistant FRP with rigid frame construction
            • - Enhanced longevity with a variety of durable materials of construction
            ?image005
            ?Durable Frame Construction

            填充圖片

            Reliable Year-Round Operation

            - Separate air intake louvers for easy visual inspection of the air-water interface
            - BALTIDRIVE??Power Train Fan System

            • ? a. BAC specified motor brand
            • ? b. Corrosion resistant cast aluminum sheaves with specially designed powerband belts
            • ? c. Cooling tower duty motors designed for hostile environments
            ?image006
            ?BALTIDRIVE? Power Train Fan System

            填充圖片

            Easy Maintenance

            - Crossflow configuration provides direct access for easy maintenance
            - BALTIDRIVE??Power Train uses state-of-the-art technology to ease maintenance
            - Patented hygienic cold water basin is sloped at the air intakes to eliminate stagnant water and reduce biological growth
            - Fill surface is elevated above the sloped cold water basin floor to facilitate flushing of dirt and debris
            - Hinged access doors provide easy access to the cold water basin and fan drive system
            - Combined inlet shields block sunlight, reducing the potential for algae growth in the cold water basin (option)
            - Louver face platforms, internal service platforms, and internal walkways simplify maintenance (option)
            ?image007

            ?Louver Face Platforms

            填充圖片

            Easy Installation

            image008
            Flexible Piping Arrangement

            填充圖片

            填充圖片

            • - Rigging guides ensure?proper alignment and reduce rigging time- Flexible inlet/outlet piping connection locations ensure proper fit for any applications
            • - Adaptable steel support configuration options, utilizing pre-existing support steel
            • - Knockdown units available for field assembly
            • - EASY CONNECT? ?Piping Arrangement reduces installation costs by eliminating overhead piping and piping support requirements (option)
            • - Basinless construction ability, ideal for installations using a common sump for multiple tower cells (option)
            ?